¾Mark the fixing positions in accordance with fixing dimensions (see figure 1 and 2
above.) There are three holes to be drilled/tapped on the door leaf for the closer body and
four holes to be drilled/tapped on the underside of the transom for the parallel arm bracket.
¾Separate the primary and secondary arms. This can be done using a screwdriver as a
lever. The arm sections will snap together and apart. Secure the primary arm to the spindle
using M6 allen bolt supplied. Ensure splines are interlocked. Locate arm at approx. 10°
towards the rear of the closer. (See figure 3 and 4.) Turn closing speed valve, located on
the front of the body of the closer fully clockwise. This will decrease the closing speed to
almost zero. Do not overtighten. Rotate primary arm to approximately 90°. (See figure 5
and 6.) Secure closer body to door leaf with fixings provided, making sure that the spindle
is positioned away from the hinge side. (See figure 1 and 2 above.) The power size
(closing force) of the TS2000 is not adjustable in this configuration and the unit must be
mounted using the centre fixing holes. Secure primary and secondary arms together
(simply click in place.)
¾Rotate primary arm in direction of travel (away from door leaf) until an angle of approx. 2°
is reached in relation to the door leaf. (See figure 7 and 8.) Tighten 10mm locking bolt.
¾TS2000 only. For TS2000 BC see below. If latch action is required (to overcome a latch
or seals) fit closer as described above.
¾TS2000 only. For TS2000 BC see below. If no latch action is required. Fit closer as
described above. Separate the primary and secondary arms. Turn closing speed valve,
located on the front of the body of the closer fully clockwise. This will decrease the closing
speed to almost zero. Do not overtighten. Rotate the primary arm approx. 90° in the
direction of travel (roughly perpendicular to the door leaf.) Loosen the M6 allen bolt
securing the primary arm to the closer body enough to enable adjustment. Rotate the
primary arm 1 notch of the splined spindle in the opposite direction of travel. Re-tighten
M6 allen bolt securing the primary arm to the closer body. Loosen 10mm locking bolt on
secondary arm and re-connect primary and secondary arms. Re-adjust the closing speed.
Rotate primary arm in direction of travel (away from door leaf) until an angle of approx. 2°
is reached in relation to the door leaf. (See figure 7 and 8.) Tighten the 10mm locking bolt.
If on testing the latch action has not been removed repeat above until adjusted
satisfactorily.
¾TS2000 BC. Note: If backcheck is required to come in at any opening angle less than
100° then latch action is not possible with this unit.
The back check is a segment of the closers opening cycle with increased resistance. In
this configuration it is factory set to come in when the door is at approx. 100°. In order to
bring this in earlier fit closer as described above. Separate the primary and secondary
arms. Turn closing speed valve, located on the front of the body of the closer fully
clockwise. This will decrease the closing speed to almost zero. Do not overtighten. Rotate
the primary arm approx. 90° in the direction of travel (roughly perpendicular to the door
leaf.) Loosen the M6 allen bolt securing the primary arm to the closer body enough to
enable adjustment. Rotate the primary arm 1 notch of the splined spindle in the opposite
direction of travel. Re-tighten M6 allen bolt securing the primary arm to the closer body.
Loosen 10mm locking bolt on secondary arm and re-connect primary and secondary arms.
Re-adjust the closing speed. Rotate primary arm in direction of travel (away from door leaf)
until an angle of approx. 2° is reached in relation to the door leaf. (See figure 5 and 6.)
Tighten the 10mm locking bolt. If on testing the back check is still not early enough repeat
above until adjusted satisfactorily
If the unit has not been adjusted to bring the backcheck in earlier then the latch action of
the TS2000 BC can now be adjusted using the adjustment valve located on the front of the
body of the closer next to the closing speed adjustment valve. Clockwise will decrease the
latch action and anticlockwise will increase the latch action. Do not overtighten.
¾The closing speed can now be adjusted using the adjustment valve located on the front
of the body of the closer. Clockwise will decrease the closing speed and anticlockwise will
increase the closing speed. Do not overtighten.
Fixing in figure 66